Mainframes
Hot Runner Controls
TC-2000 Main Frames Standard 15 Amp. Index
1 Zone Main Frame MF-1 |
2 Zone Main Frame MF-2 |
|
![]() |
![]() |
|
Max. Amperage | 15 Amps | Total of 20 Amps for system |
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
|
Mold Interface | Accomplished through 1 single 5 wire cable construction of 2 thermocouple leads, 2 power leads and 1 ground lead per zone. |
|
Vital Feature | Anti-Arching circuitry |
|
Construction | Steel frame with handle; air vent on bottom & side for cooling; top & bottom module insertion guides; 4 rubber feet; 3 pin male AC input socket installed on top of main frame; 5 pin female power/thermocouple connector (1Z-FC) with latch installed on top of main frame and 3 prong input power cord plug (1Z-PP without input cord) is supplied. NOTE : If a power/thermocouple cable (PTC-1) is not ordered with main frame, 1 or 2 male cable connector/s (1Z-ME) will be provided. |
|
Dimensions & Weight | 9″ (H) x 7″ (W) x 11.5″ (D); Approx. 7 lbs (without modules & cables) |
|
Compatibility | Compatible with industry standard control modules and main frames |
Five Zone Main Frame MF-5-150 | |||
Max. Amperage | 15 Amps per zone | ![]() |
|
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
||
Circuit Breaker | 50 Amps, 3 Pole ** | ||
Vital Feature | Anti-Arching circuitry |
||
Thermocouple | Type “J” | ||
Mold Interface | Accomplished through dedicated power cord with ground (PWC-5) and Thermocouple cable (THC-5) |
||
Construction | Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) & Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the main frame. Input power cord grip is mounted on RHS of the main frame (input power cord in not supplied). Completely self contained with no external components required. PFS-5 Floor Stand can be used to mount the main frame. It accepts all ITC temperature control modules. |
||
Dimensions & Weight | 9″ (H) x 20.25″ (W) x 11.5″ (D); Approx. 15 lbs (without modules & cables) | ||
Compatibility | Compatible with industry standard control modules and main frames | ||
Eight Zone Main Frame MF-8-150 | Sixteen Zone Main Frame
MF-16-170 |
Sixteen Zone Main Frame
MF-16-250 |
|
![]() |
![]() |
![]() |
|
Circuit Breaker | (1) 50 Amps, 3 Pole ** | (1) 70 Amps, 3 Pole ** | (2) 50 Amps, 3 Pole ** |
Single 8 Zone main frame construction | Two 8 Zone Main Frames stacked construction | Two 8 Zone Main Frames stacked construction | |
Max. Amperage | 15 Amps per zone | ||
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
||
Vital Feature | Anti-Arching circuitry |
||
Thermocouple | Type “J” | ||
Mold Interface | Accomplished through dedicated power cord with ground (PWC-8) and Thermocouple cable (THC-8) |
||
Construction | Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) & Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the main frame. Input power cord grip is mounted on RHS of the main frame (input power cord in not supplied). Completely self contained with no external components required. PFS-812 Floor Stand can be used to mount the main frame. It accepts all ITC temperature control modules. |
||
Compatibility | Compatible with industry standard control modules and main frames |
||
Dimensions & Weight (without modules & cables) |
9″ (H) x 20.25″ (W) x 11.5″ (D); Approx. 15 lbs | 18″ (H) x 20.25″ (W) x 11.5″ (D); Approx. 32 lbs |
18″ (H) x 20.25″ (W) x 11.5″ (D); Approx. 32 lbs |
Twelve Zone Main Frame MF-12-150 | Twenty Four Zone Main Frame MF-24-250 |
Thirty Six Zone Main Frame MF-36-350 |
|
![]() |
![]() |
![]() |
|
Circuit Breaker | (1) 50 Amps, 3 Pole ** | (2) 50 Amps, 3 Pole ** | (3) 50 Amps, 3 Pole ** |
Modular Construction | Single 12 Zone main frame construction | Two 12 Zone Main Frames stacked construction. Rigidly connected & pre-wired. |
Three 12 Zone Main Frames stacked construction. Rigidly connected & pre-wired. |
Dimensions & Weight (without modules & cables) |
9″ (H) x 28.25″ (W) x 11.5″ (D); Approx. 20 lbs |
18″ (H) x 28.25″ (W) x 11.5″ (D); Approx. 42 lbs |
27″ (H) x 28.25″ (W) x 11.5″ (D); Approx. 66 lbs |
Max. Amperage | 15 Amps per zone | ||
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
||
Vital Feature | Anti-Arching circuitry |
||
Thermocouple | Type “J” | ||
Mold Interface | Accomplished through dedicated power cord with ground (PWC-12) and Thermocouple cable (THC-12) |
||
Construction | Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) & Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the main frame. Input power cord grip is mounted on RHS of the main frame (input power cord in not supplied). Completely self contained with no external components required. PFS-812 Floor Stand can be used to mount the main frame. It accepts all ITC temperature control modules. | ||
Compatibility | Compatible with industry standard control modules and main frames |
||
Twenty Zone Mainframe MF-20-170 | Twenty Zone Mainframe MF-20-250 | |
Circuit Breaker | (1) 70 Amps, 3 Pole ** | (2) 50 Amps, 3 Pole ** |
Modular Construction | 8 Zone Main Frame is mounted on 12 Zone Main Frame. Rigidly connected & pre-wired. |
8 Zone Main Frame is mounted on 12 Zone Main Frame. Rigidly connected & pre-wired. |
Dimensions & Weight (without modules & cables) | 18″ (H) x 28.25″ (W) x 11.5″ (D); Approx. 37 lbs |
|
Max. Amperage | 15 Amps per zone | |
Power | 240 VAC, Single Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
|
Vital Feature | Anti-Arching circuitry |
|
Thermocouple | Type “J” | |
Mold Interface | Accomplished through dedicated power cord with ground (PWC-12 & PWC-8) and Thermocouple cable (THC-12 & THC-8) | |
Construction | Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) & Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the main frame. Input power cord grip is mounted on RHS of the main frame (input power cord in not supplied). Completely self contained with no external components required. PFS-812 Floor Stand can be used to mount the main frame. It accepts all ITC temperature control modules. | |
Compatibility | Compatible with industry standard control modules and main frames |
|
Hot Runner Controls
High Power 30 Amp. Main Frames Index
ITC’s High Power (up to 30 Amps.) Temperature Control Systems are uniquely engineered to control mold temperature for 1 to 6 zone application without the need for special temperature control modules. The Main Features of High Power Main Frame systems (MFHP-30) are:
- Uses Standard Temperature Modules (S20-D3C or UTC-20 ) which are used for our 15 Amp. system. This eliminate the need of high amperage modules. Using one style modules for 15 Amp. and 30 Amp. system will give you following benefits :
- Eliminate the need for special double wide, high cost control modules.
- Reduce the possible system damage due to inserting wrong module in main frame slot.
- Reduce total system cost and inventory cost.
- Full Load Capacity High Power main frames are designed to operate under full load capacity. This means Sequential Startup is not required.
- Amperage Display The heater amperage draw for each zone can checked by turning the selector switch to appropriate zone and pressing the amp button next to it. The display will indicate amperage draw for the selected zone. This feature allows to use control modules without amperage readout.
- Easy Installation All 30 Amp. (High Power) main frames are completely self contained and easy to install. Hook the main power, 240 VAC, and attach mold power and thermocouple cables to main frame.
- Protection Each heater zone is protected by pair of 30 Amp. fuses and the main frame is equipped with appropriate circuit breaker.
- Anti-Arching This feature is designed in the main frame to protect damage to both, main frame and module, in an event a module is inadvertently removed while under load. This feature will function only in newer ITC control modules, which are equipped with modified circuitry.
- Phase Indicators, indicate which leg has power. High Power main frames are configured to fit our regular stands and can be tied together with our standard 15 Amp. main frame.
1 Zone High Power Main Frame MFHP-1-130
Max. Amperage | 30 Amp. Per Zone | |
Power | 208 to 240 VAC, Single Phase, 50/60 Hz. | |
Vital Feature | Anti-Arching capability with proper ITC modules | |
Amperage Display | 3 Digits, 7 Segment LED Display | |
System Overcurrent Protection | 2 Pole, 30 Amp. Circuit Breaker, with phase indicator. | |
Zone Overcurrent Protection | 2 – 30 Amp. fuses for each zone. (externally accessible) | |
Physical Configuration | Welded steel durable construction, with steel handle and high amperage rating connectors. 10.75″ (H – with handle) x 7.25″ (W) x 15.25″ (D), Approx. 10 lbs., Chicory dark tan color. | |
Compatibility | With any standard ITC control modules (S20-D3C or UATC-20 ) |
3 Zone High Power Main Frame MFHP-3-170
Max. Amperage | 30 Amp. Per Zone | |
Power | 208 to 240 VAC, Three Phase, 50/60 Hz. | |
Vital Feature | Anti-Arching capability with proper ITC modules | |
Amperage Display | 3 Digits, 7 Segment LED Display | |
System Overcurrent Protection | 3 Pole, 70 Amp. Circuit Breaker, with phase indicator. | |
Zone Overcurrent Protection | 2 – 30 Amp. fuses for each zone. (externally accessible) | |
Physical Configuration | Welded aluminum durable construction, with high amperage rating connectors and sized to fit our standard stands. 9″ (H) x 14.25″ (W) x 15.25″ (D), Approx. 23 lbs., Chicory dark tan color. | |
Compatibility | With any standard ITC control modules (S20-D3C or UATC-20 ) |
6 Zone High Power Main Frame MFHP-6-1100
Max. Amperage | 30 Amp. Per Zone | ![]() |
Power | 208 to 240 VAC, Three Phase, 50/60 Hz. | |
Vital Feature | Anti-Arching capability with proper ITC modules | |
Amperage Display | 3 Digits, 7 Segment LED Display | |
System Overcurrent Protection | 3 Pole, 100 Amp. Circuit Breaker, with phase indicator. | |
Zone Overcurrent Protection | 2 – 30 Amp. fuses for each zone. (externally accessible) | |
Physical Configuration | Welded aluminum durable construction, with high amperage rating connectors and sized to fit our standard stands. 12.75″ (H) x 20.25″ (W) x 15.25″ (D), Approx. 35 lbs., Chicory dark tan color. | |
Compatibility | With any standard ITC control modules (S20-D3C or UATC-20 ) |