VULCAN SYSTEM

The muscle man among the hot-air blowers leaves no doubts about its performance. It is compactly built and easy to integrate into industrial processes. Just as Leister’s smaller hot-air blowers, VULCAN SYSTEM can be controlled remotely through a standard analog interface.
Specifications
VULCAN SYSTEM – 3 × 230 V / 6 kW
Article No.: 143.407
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 230 |
Power | W | 6000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlettemperature | °F | 1202 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Pressure | psi | 0.45 – 0.59 |
Noise emission level | dB(A) | 65 |
Size (L × W × H) | inch | 16.14 × 10.86 × 9.09 |
Weight | lbs | 20.5 |
Conformity mark | ![]() |
|
Approval mark | ![]() |
|
Protection class I | ![]() |
VULCAN SYSTEM – 3 × 230 V / 10 kW
Article No.: 143.406
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 230 |
Power | W | 10000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlettemperature | °F | 1202 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Pressure | psi | 0.45 – 0.59 |
Noise emission level | dB(A) | 65 |
Size (L × W × H) | inch | 16.14 × 10.86 × 9.09 |
Weight | lbs | 20.5 |
Conformity mark | ![]() |
|
Approval mark | ![]() |
|
Protection class I | ![]() |
VULCAN SYSTEM – 3 × 400 V / 6 kW
Article No.: 143.402
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 400 |
Power | W | 6000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlettemperature | °F | 1202 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Pressure | psi | 0.45 – 0.59 |
Noise emission level | dB(A) | 65 |
Size (L × W × H) | inch | 16.14 × 10.86 × 9.09 |
Weight | lbs | 20.5 |
Conformity mark | ![]() |
|
Approval mark | ![]() |
|
Protection class I | ![]() |
VULCAN SYSTEM – 3 × 400 V / 11 kW
Article No.: 140.463
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 400 |
Power | W | 11000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlettemperature | °F | 1202 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Pressure | psi | 0.45 – 0.59 |
Noise emission level | dB(A) | 65 |
Size (L × W × H) | inch | 16.14 × 10.86 × 9.09 |
Weight | lbs | 20.5 |
Conformity mark | ![]() |
|
Approval mark | ![]() |
|
Protection class I | ![]() |
VULCAN SYSTEM – 3 × 480 V / 6 kW
Article No.: 143.405
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 480 |
Power | W | 6000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlettemperature | °F | 1202 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Pressure | psi | 0.45 – 0.59 |
Noise emission level | dB(A) | 65 |
Size (L × W × H) | inch | 16.14 × 10.86 × 9.09 |
Weight | lbs | 20.5 |
Conformity mark | ![]() |
|
Approval mark | ![]() |
|
Protection class I | ![]() |
VULCAN SYSTEM – 3 × 480 V / 11 kW
Article No.: 143.404
Attribute | Unit | Value |
---|---|---|
Voltage | V~ | 3 × 480 |
Power | W | 11000 |
Heating power steplessly adjustable with potentiometer | • | |
Standard control interface through a | 4 – 20 mA or a 0 – 10 V signal | • |
Integrated power electronics | • | |
Protection against heating element or device overheating | • | |
Brushless blower motor with FC control | • | |
Alarm output | • | |
Integrated temperature control | • | |
Integrated temperature probe | • | |
Display for showing the setpoint and actual values | • | |
Max. air outlettemperature | °F | 1202 |
Max. air flow (20°C) 3 × 230 V~ | l/min | 850 1500 |
Max. air flow (20°C) 400 V~ / 3 × 480 V~ | l/min | 950 1700 |
Pressure | kPa | 3.1 – 4.0 |
Pressure | psi | 0.45 – 0.59 |
Noise emission level | dB(A) | 65 |
Size (L × W × H) | inch | 16.14 × 10.86 × 9.09 |
Weight | lbs | 20.5 |
Conformity mark | ![]() |
|
Approval mark | ![]() |
|
Protection class I | ![]() |