40 Series

 

40A48-96 AC current / voltage configurable indicator-alarm units

 

  • AC voltage, AC current direct input on instrument terminals
  • Protected code configurable from keypad
  • 4 to 20mA retransmitted output
  • Up to 3 relay outputs
  • Configurable by serial link
  • Labels to customize measured physical unit

Microprocessor based indicator in both 48×48 (1/16 DIN) and 96×48 (1/8 DIN) formats manifactured with SMT. T
he instruments have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 3 digit display for the 48×48 format and a 3 / 4 digit display for the 96×48 format, and 3 indicating LED’s for the output statuses.
The input signal section provides for the visualisation of the sinusoidal effective value corresponding to following signals:

  • AC voltage: 0 to 2, 0 to 20, 0 to 200 and 0 to 500Vac
  • AC current: 0 to 20, 0 to 50, 0 to 200mAac 0 to 1, 0 to 5Aac

The selection is made using the faceplate keys and correct input terminals.
No external shunt or adapter is required.
A digital input (24Vdc/4mA) is available for resetting, hold, flash, peak handling or releasing latch.
The instruments have a maximum of 3 outputs that can be mechanical relays (5A/250V) or logic outputs (0 to 11Vdc).
One output of 4 to 20mA (max. 150W) is available for retransmitting the measured input signal.
The retransmission output, the digital input and the third output are alternatives in the 48×48 format, all these options are available contemporaneously in the 96×48 format.
Finally, a triac can be fitted (as an alternative to the other two relay outputs) to drive resistive loads up to a maximum of 2,5A at 220V.
The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs…) and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (see data sheet cod. 80021).
A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.

40B96 Force, pressure and displacement transducer indicator with input for strain-gauge or potentiometer

  • Strain-gauge or potentiometer input -configurable by faceplate
  • Sensor supply check
  • Easy to calibrate with sensitivity auto-ranging
  • Protected by a personal code
  • Configurable by serial link
  • Internal linearisation for engineering units
  • Labels provided for the more common physical units
  • Sampling time and trip intervention programmable between 15 and 120msec with resolution between 4000 and 30000 steps
  • Retransmission of the measured variable signal
  • 4 trip points, completely configurable from the faceplate
  • 6 wires calibration o Version for magnetostrictive sensors

96×48 (1/8 DIN) formats manufactured with SMT.
The instruments have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 5 digit display and 4 indicating LED’s for the output statuses.
The input signal can be selected from a wide range of sensors:

  • Potentiometer (minimum 100W)
  • Load cell with sensitivity autoranging between 1,5 and 3,3mV/V
  • Strain-gauge pressure sensor

The selection is made using the faceplate keys.
A digital input (24Vdc/5mA) is available for resetting, hold, flash, peak handling or releasing latch.
The instruments have a maximum of 4 outputs that can be mechanical relays or logic outputs.
One output of 0/4 to 20mA (max. 500W) is available for retransmitting the measured input signal.
The retransmission output, the digital input and the third output are options available contemporaneously.
Finally, a triac can be fitted to drive resistive loads up to a maximum of 1A at 240V.
The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs…) and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (data sheet cod.WINSTRUM).
A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.

40B48 Force, pressure and displacement transducer indicator with input for strain-gauge or potentiometer

  • Strain-gauge or potentiometer input -configurable by faceplate
  • Sensor supply check
  • Easy to calibrate with sensitivity auto-ranging
  • Protected by a personal code
  • Configurable by serial link
  • Internal linearisation for engineering units
  • Labels provided for the more common physical units
  • Sampling time and trip intervention programmable between 15 and 120msec with resolution between 2000 and 8000 steps
  • Retransmission of the measured variable signal
  • 3 trip points, completely configurable from the faceplate

48×48 (1/16 DIN) formats manufactured with SMT.
The instruments have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 4 digit display and 3 indicating LED’s for the output statuses.
The input signal can be selected from a wide range of sensors:

  • Potentiometer (minimum 100W)
  • Load cell with sensitivity autoranging between 1,5 and 3,3mV/V
  • Strain-gauge pressure sensor

The selection is made using the faceplate keys.
A digital input (24Vdc/4mA) is available for resetting, hold, flash, peak handling or releasing latch.
The instruments have a maximum of 3 outputs that can be mechanical relays (5A/250V) or logic outputs (0 to 11Vdc).
One output of 4 to 20mA (max. 150) is available for retransmitting the measured input signal.
The retransmission output, the digital input and the third output are alternative.
The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs…) and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (see data sheet cod. WINSTRUM).
A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.

40T72 Configurable indicator

  • Faceplate configurable input
  • Protected by a personal code
  • Configurable by a serial link
  • Transmitter power supply incorporated
  • Custom thermocouple linearisation available
  • Internal linearisation for engineering units
  • Labels provided for the more common physical units
  • Sampling time and trip intervention programmable between 15 and 120 msec with resolution between 2000 and 8000 steps
  • Retransmission of the measured variable signal
  • 3 trip points, completely configurable from the faceplate

Microprocessor based indicator in 72×36 format manufactured with SMT.
The instruments have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 2, 3 / 4 digit display.
The input signal can be selected from a wide range of sensors:

  • Thermocouples of type J, K, R, S, T, B, E, N, L GOST, U, G, D, C
  • Resistance thermometers Pt100, Pt100J (Japanese standard) 2 / 3 wire
  • PTC and NTC themistors
  • Linear inputs 0 to 60/12 to 60mV, 0 to 20/4 to 20mA, 0 to 10/2 to 10/0 to 5/1 to 5/0 to 1/0, 2 to1V

The selection is made using the faceplate keys and correct input contact.
No external shunt or adapter is required.
A digital input (24Vdc/4mA) is available for resetting, hold, flash, peak handling or releasing latch. The instruments have a maximum of 3 outputs that can be mechanical relays (5A/250V) or logic outputs (0 to 11Vdc).
In alternative to output 3 a 4 to 20mA output is available (max. 150 Ohm) for retransmission of the measured input signal, or a digital input (24Vdc/4mA) can be provided which can be used for resetting, hold, flash, peak handling or releasing latch.
Finally, a triac can be fitted (as an alternative to the other two relay outputs) that can drive resistive loads up to a maximum of 2,5A at 220V.
The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs…) and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (see data sheet cod. 80021).
A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.

40T96 Configurable indicators – alarm units

  • Faceplate configurable input
  • Protected by a personal code
  • Configurable by a serial link
  • Transmitter power supply incorporated
  • Custom thermocouple linearisation available
  • Internal linearisation for engineering units
  • Labels provided for the more common physical units
  • Sampling time and trip intervention programmable between 15 and 120msec with resolution between 4000 and 16000 steps
  • Retransmission of the measured variable signal
  • 4 trip points completely configurable from keyboard
  • RS485 optically isolated serial line
    Protocol: GEFRAN CENCAL or MODBUS RTU
  • Rapid configuration from PC with Winstrum package

Microprocessor based indicator in both 96×48 (1/8 DIN) format manufactured with SMT.
The instrument have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 3 / 4 digit display format, and 3 indicating LED’s for the output statuses.
The input signal can be selected from a wide range of sensors:

  • Thermocouples of type J, K, R, S, T, B, E, N, L GOST, U, G, D, C
  • Resistance thermometers Pt100, Pt100J (japanese standard) 2 / 3 wire
  • PTC and NTC themistors
  • Linear inputs 0 to 60/12 to 60mV, 0 to 20/4 to 20mA, 0 to 10/2 to 10/0 to 5/1 to 5/0 to 1/0, 2 to1V

The selection is made using the faceplate keys.
The instrument is available in version base, with two outputs to rel (2R), and expandible version.
The instruments have a maximum of 4 outputs that can be mechanical relays (5A,250Vac/30Vdc cos=1) or logic outputs (0 to 11Vdc).
A digital input (24Vdc/5mA) is available (for resetting, hold, flash, peak handling or releasing latch) and one output of 0…10V, 0/4 to 20mA (max. 500) is available for retranmitting the measured input signal.
The retransmission output, the digital input and the third output are available contemporaneously.
The serial communication option (available in RS485 standard) allows connection to supervision systems and PLCs with two protocols: GEFRAN CENCAL and MODBUS RTU.
Finally, a triac can be fitted (as an alternative to the output 1) to drive resistive loads up to a maximum of 1A at 240V.
The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs…) and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (see technical data WINSTRUM).
A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.

40T48 Configurable indicators – alarm units

  • Faceplate configurable input
  • Protected by a personal code
  • Configurable by a serial link
  • Transmitter power supply incorporated
  • Custom thermocouple linearisation available
  • Internal linearisation for engineering units
  • Labels provided for the more common physical units
  • Sampling time and trip intervention programmable between 15 and 120msec with resolution between 2000 and 8000 steps
  • Retransmission of the measured variable signal
  • 3 trip points, completely configurable from the faceplate
  • 4 trip points completely configurable from keyboard
  • RS485 optically isolated serial line
    Protocol : GEFRAN CENCAL or MODBUS RTU
  • Rapid configuration from PC with Winstrum package

Microprocessor based indicator in both 48×48 (1/16 DIN) formats manufactured with SMT.
The instruments have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 4 digit display and 3 indicating LED’s for the output statuses.
The input signal can be selected from a wide range of sensors:

  • Thermocouples of type: J, K, R, S, T, B, E, N, L GOST, U, G, D, C
  • Resistance thermometers Pt100, Pt100J 2 / 3 wire
  • PTC and NTC themistors
  • Linear inputs 0 to 60/12 to 60mV, 0 to 20/4 to 20mA, 0 to 10/2 to 10/0 to 5/1 to 5/0 to 1/0, 2 to1V

The selection is made using the faceplate keys and correct input terminals.
No external shunt or adapter is required. A digital input (24Vdc/4mA) is available for resetting, hold, flash, peak handling or releasing latch.
No external shunt or adapter is required. A digital input (24Vdc/5mA) is available for resetting, hold, flash, peak handling or releasing latch. The instruments have a maximum of 4 outputs that can be mechanical relays (5A/250V) or logic outputs 24V±10% (10Vmin / 20mA).
One output of 4 to 20mA (max. 500 Ohm) is available for retranmitting the measured input signal.
The retransmission output, the digital input and the third output are alternatives.
The options include a triac output that can directly drive resistive loads up to a maximum of 1A at 240V.
The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs…) and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (see technical data).
A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.

40F96 Configurable frequency meter alarm unit – indicator

  • Input from the most common types of sensor
  • Protected by a code configurable from keypad
  • 4 to 20mA retransmitted output
  • Up to 3 relay outputs
  • Configurable by a serial link
  • Labels to customize measured physical unit

Microprocessor based indicator in 96×48 (1/8 DIN) format manufactured with SMT.
The instruments have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 4 digit display and 3 indicating LED’s for the output statuses.
The input signal can be selected from a wide range of sensors:

  • voltage free mechanical contact
  • inductive or capacitive proximity switch, encoder or Namur 2 / 3 wires
  • 30 to 500Vac, 1mA alternating voltage command

The selection is made using the faceplate keys.
A digital input (24Vdc/4mA) is available for resetting, hold, flash, peak handling or releasing latch.
The instruments can have a maximum of 3 outputs that can be mechanical relays (5A/250V) or logic outputs (0 to 11Vdc).
One output of 4 to 20mA (max. 150W) is available for retransmitting the measured input signal.
Finally, a triac can be fitted (as an alternative to the other two relay outputs) to drive resistive loads up to a maximum of 2,5A at 220V.
The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs…) and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (see technical data cod. 80021).
A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.

40TB Temperature and pressure double indicator / alarm unit

  • Inputs configurable from faceplate.
  • Easy strain-gauge calibration with sensitivity auto-ranging.
  • Control of sensor power supply (input 1).
  • Selectable code protection.
  • Possibility to configure the unit.
  • Power supply for transmitters.
  • Easy to configure . Custom linearization available.
  • Engineering units of the most common physical quantities available either on display or on labels.
  • Acquisition and alarm programmable from 15 up to 120 msec. with resolution from 16000 to 4000 divisions
  • Retransmission of variable values
  • 3 alarms completely configurable from faceplate.
  • 4-wire, configurable serial line. Protocol: GEFRAN CENCAL or MODBUS

PROFILE The 40 TB is a microprocessor based, 2-channel alarm unit, format 96×96 (1/4 DIN), manufactured with SMT.
Its operator interface is comprehensive and efficient, with two 4-digit displays for the two process variables and engineering units indications.
It is also equipped with a red LED bargraph, which can be associated to process variables and to peak values.
Three LEDs indicate the output status, while 3 more LEDs can be configured to indicate different functional conditions.
The instrument has a lexan membrane faceplate (guaranteed to IP65) with 4 keys.
Channel 1 has strain gauge, pressure or force sensor inputs, with positive or symmetrical polarisations, calibration with sensitivity auto-calculation (from 1,5 up to 4 mV/V), indication of probe power supply break.
The first input channel can also receive signals from potentiometers with 100 Ohm min. resistance.
The A/D converter performance can be configured via keyboard, so that different options of sampling time can be selected, depending on the desired resolution.
Sampling time can be as low as15msec., while resolution can reach a max. value of 16,000 divisions (by a 120msec. sampling time).
The second input channel can be configured for inputs from temperature sensors (TC, RTD, PTC, NTC) and for mV, V, mA signals, with the ability to have of having a customized input for each kind of sensor.
The selection of the different options is available from keyboard. There is the possibility of having two digital inputs from voltage-free contacts, configurable for functions such as reset, hold, flash, peak or memory reset control.
The instruments can be equipped with up to three relay (5A/250V) or static (0-11Vdc) outputs. Two voltage or current analogue outputs are available for the retransmission of inputs, of alarm sets, of gross and tare values.
The serial communication option may have current loop, RS422/ 485 and RS232 connections with baud rate up to 19200.
The option “transmitter power supply” is foreseen for each input channel. For channel 1 it could be: 1V (potentiometer), 5 and 10V (strain-gauge), 15 and 24V; for channel 2: 15 and 24Vdc.
The programming of the instrument is made easy by grouping the parameters in function blocks and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit containing connection cable and a menu guide program that runs under Windows (see technical data code 80020). A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.